Arc Welding

QUBOX / QUBOX PULSE

BACK TO WELD
SYNERGIC MULTIPROCESS INVERTER PULSE EQUIPMENT WITH SEPARATE WIRE FEEDER
QUBOX and QUBOX PULSE series multiprocess equipment are characterized by a synergic digital control and inverter technology integrated into a sturdy and functional metallic structure, with a separate wire feeder. Technologically advanced, robust and easy-to-use, they allow high quality welding in MMA, TIG with Lift mode, MIG-MAG and with the QUBOX PULSE models, also in PULSED MIG.
MIG/MAG | PULSED MIG | MMA | TIG LIFT
Full synergic control
The intuitive interface allows less experienced operators to easily operate QUBOX and QUBOX PULSE equipment with a user-friendly welding parameters adjustment process. Once the wished program has been selected, the welding control automatically sets the best parameters based on the material type, wire diameter and gas being used.
Professional and strong
QUBOX and QUBOX PULSE are the best choice in all industrial fields for all qualified applications requiring high precision and repeatability of the welding results, such as medium and large fabrication work, shipyards and steel erection. QUBOX W and QUBOX W PULSE power sources are fitted with integrated cooling equipment.

Other Characteristics

  • Digital control of the welding parameters with synergic curves preset
  • Smart PROGRAM key for quickly selecting any program
  • Energy saving to operate the power source cooling fan and torch water cooling only when necessary
  • Excellent arc striking
  • Ability to partially or totally lock the equipment with access key by password
  • Initial and final crater control
  • Water cooling equipment integrated into the power source (W version)

QUBOX / QUBOX PULSE: Technical Features

TECHNICAL DATA QUBOX QUBOX PULSE
400 400 W 500 W 335 335 W 405 W 505 W
Three phase input 50/60 Hz V +20% -20% 400 400
Input Power @ I2 Max kVA 22 22,5 29,5 18,5 22,5 29,5
Delayed Fuse (l eff) A 32 40 20 32 40
Power Factor / cos φ 0,70/0,99 0,75/0,99 0,65/0,99 0,70/0,99 0,75/0,99
Efficiency Degree 0,88 0,89 0,88 0,88 0,89
Open circuit voltage V 62 62 62 62 62
Current range A 10-400 10-500 10-330 10-400 10-500
Duty cycle at (40°C) A 100% 340 420 300 350 420
A 60% 400 500 330 400 500
Wires Ø mm 0,6-1,6 0,6-1,6 0,6-1,6 0,6-1,6 0,6-1,6
Standards EN 60974-1 • EN 60974-5 • EN 60974-10
Protection Class IP 23S 23S
Dimensions (LxWxH) mm 1030 x 950 x 515 1030 x 950 x 515
Weight kg 70 / 80 / 86 70 / 80 / 80 / 86